What Ontario Building Code sections apply to exterior stucco and rendering work?
What Ontario Building Code sections apply to exterior stucco and rendering work?
Understanding which OBC sections govern your stucco project helps you have informed conversations with your contractor and ensures the work meets code. Here's a practical guide to the relevant sections for residential stucco work in Ottawa.
Key OBC Sections for Stucco and Rendering
Part 9 — Housing and Small Buildings is the primary section for most Ottawa residential stucco projects (buildings up to 3 storeys, 600 m² per floor):
Section 9.27 — Cladding: This is your main section. It covers exterior cladding requirements including stucco (referred to as "cement plaster" or "Portland cement stucco" in the code). Key provisions include:
- 9.27.4 — Stucco application requirements, including minimum thickness (typically 19mm or ¾ inch for three-coat systems), wire mesh specifications, and application over different substrates- 9.27.3 — Cladding attachment and structural adequacy, including resistance to wind loads and the weight of the stucco system itself (Portland cement stucco weighs approximately 10-12 lbs per square foot for a three-coat system)- 9.27.2 — Moisture protection behind cladding, requiring a weather-resistant barrier (building paper, housewrap) with proper lapping and integration with window/door flashings
Section 9.26 — Moisture Protection: Covers the rain screen principle, drainage behind cladding, and flashing requirements. For stucco specifically, this section requires:
- A minimum 19mm drainage space or equivalent drainage provision behind the stucco- Flashing at the base of stucco walls with weep holes at maximum 800mm centres- Proper integration of flashings at window heads, sills, and wall-roof intersections
Part 5 — Environmental Separation applies to larger buildings (Part 3 buildings) and provides the engineering principles behind moisture management, air barriers, and thermal performance that inform Part 9's prescriptive requirements.
Referenced standards you'll see in specifications:
- ASTM C926 — Standard Specification for Application of Portland Cement-Based Plaster- ASTM C1063 — Standard Specification for Installation of Lathing and Furring to Receive Interior and Exterior Portland Cement-Based Plaster- CAN/ULC S716 — for EIFS specifically
---
Looking for experienced contractors? The Ottawa Construction Network connects Ottawa homeowners with qualified professionals:
View all contractors →Stucco IQ -- Built with local stucco and exterior finishing expertise, Ottawa knowledge, and real construction experience. Answers are for informational purposes only.
Ready to Start Your Stucco Project?
Find experienced stucco contractors in Ottawa. Free matching, no obligation.